Kayunga District

by December 6, 2022

The access rates in Kayunga vary from 48 % in Kitimbwa Sub-County to 95 % in Kayunga TC Sub-County. Kayunga has 1,070 domestic water points which serve a total of 294,024 people – 264,429 in rural areas. 139 water points have been non-functional for over 5 years and are considered abandoned. Kayunga has 2 piped schemes.

Access

69%

Rural Functionality

87%

Equity

74

Management

90%

Gender

81%

Population Density (people/km2) and Population

50 250 1,000 2,000
  100 500 1,500  
KTM Kitimbwa 300
Kitimbwa
Population 300
KYA Kayunga 358
Kayunga
Population 358
BBL Bbaale 69
Bbaale
Population 69
KNG Kangulumira 565
Kangulumira
Population 565
NZG Nazigo 460
Nazigo
Population 460
GLR Galiraya 104
Galiraya
Population 104
KYN Kayonza 206
Kayonza
Population 206
KTC Kayunga TC 1,086
Kayunga TC
Population 1,086
BSN Busana 483
Busana
Population 483

Population figures are projections to the above mentioned date based on UBOS census 2014 and district growth rates. Population density is calculated on land area only. Boundaries reflect the preliminary status only.

Access to Safe Water

20 % 60 %
  40 % 80 %
Total Access 69 %
Rural Access 67 %
Urban Access 95 %

BBL Bbaale 64 %
Bbaale
Population Served 12,683
BSN Busana 62 %
Busana
Population Served 40,500
GLR Galiraya 62 %
Galiraya
Population Served 17,130
KNG Kangulumira 77 %
Kangulumira
Population Served 47,895
KTC Kayunga TC 95 %
Kayunga TC
Population Served 29,595
KTM Kitimbwa 48 %
Kitimbwa
Population Served 24,900
KYA Kayunga 86 %
Kayunga
Population Served 41,400
KYN Kayonza 61 %
Kayonza
Population Served 41,706
NZG Nazigo 77 %
Nazigo
Population Served 38,215

Access to safe water is the ratio of people served by a safe water point and piped water supply to the total population.
The calculation is based on an estimated number of people per water point type. Maximum access rate can be 95%.

Access to Safe Water

20 % 60 %
  40 % 80 %
Total Access 69 %
Rural Access 67 %
Urban Access 95 %

BBL Bbaale 64 %
Bbaale
Population Served 12,683
BSN Busana 62 %
Busana
Population Served 40,500
GLR Galiraya 62 %
Galiraya
Population Served 17,130
KNG Kangulumira 77 %
Kangulumira
Population Served 47,895
KTC Kayunga TC 95 %
Kayunga TC
Population Served 29,595
KTM Kitimbwa 48 %
Kitimbwa
Population Served 24,900
KYA Kayunga 86 %
Kayunga
Population Served 41,400
KYN Kayonza 61 %
Kayonza
Population Served 41,706
NZG Nazigo 77 %
Nazigo
Population Served 38,215

Access to safe water is the ratio of people served by a safe water point and piped water supply to the total population.
The calculation is based on an estimated number of people per water point type. Maximum access rate can be 95%.

Functionality of Point Water Sources

60 % 80 %
70 % 90 %
Rural Functionality 87 %
Urban Functionality 87 %

BBL Bbaale 80 %
Bbaale
Functional Sources 41
BSN Busana 90 %
Busana
Functional Sources 125
GLR Galiraya 76 %
Galiraya
Functional Sources 52
KNG Kangulumira 88 %
Kangulumira
Functional Sources 171
KTC Kayunga TC 87 %
Kayunga TC
Functional Sources 103
KTM Kitimbwa 88 %
Kitimbwa
Functional Sources 74
KYA Kayunga 83 %
Kayunga
Functional Sources 120
KYN Kayonza 93 %
Kayonza
Functional Sources 127
NZG Nazigo 85 %
Nazigo
Functional Sources 113

Functionality is the ratio of functional water sources to all water sources. Sources not operating for five or more years are assumed to be abandoned, and hence are not included in the calculation.

People served per technology

Reasons for non-functionality

Type of Management

Source of Funding

District Water Supply Summary

Sub-CountyUrban/
Rural
PopulationPopulation
Served
AccessFunctionalityPoint Water SourcesPiped Water Systems
Protected
springs
Shallow wellsDeep boreholesRainwater
harvesting tanks
DamsValley
tanks
PSP/Kiosk, Tap standsYTHHICNWSC
RUWfPFNFTotFNFTotFNFTotFNFTotFNFTotFNFTotFNFTot
BBAALE                               
 1 BbaaleRural19,81512,68364%80%-100%1-12-230838527---3-33-35--No
 2 KitimbwaRural52,40024,90048%89%-----551069574---------------No
 3 KayonzaRural68,58241,70661%93%--3-35-5118101281-1------------No
 4 GalirayaRural27,85117,13062%77%-100%---112341044426---1-1133169--No
Total 168,64896,41957870100404136192583229010414000404163191400No
NTENJERU                               
 1 BusanaRural65,05940,50062%90%-100%3-320828966102------1-16-610-2No
 2 KayungaRural48,21641,40086%85%-50%3-3601474551065----111-12-222--No
 3 KangulumiraRural61,86747,89577%88%--52557711182303339110------941345-No
 4 Kayunga TCUrban31,15329,59595%-87%-112181192293112-12------504541,1734186No
 5 NazigoRural49,31738,21577%85%-33%10111461460545593-31-1-22------No
Total 255,612197,6057787875069776214472612583128924125112224658731,2094688No
District 424,260294,02469878770737802275328051663579345391126288111921,2234688No

F = Functional; NF = Non-Functional; Tot = Total; YT = Yard Tap; HH = Household Connections; IC = Institutional Connections

Piped Water Supply Systems

Type of Scheme/GFSNumber of
Schemes
Functionality of SystemType of ManagementWB in place
FunctionalNon-FunctionalPartially FunctionalPrivate OperatorWSCPrivate/IndividualNWSCOtherYesNo
Groundwater based/Not GFS22002000020
Unknown/Not GFS10010000000
Groundwater based/Unknown77000700041
Total109010700061