Bugiri District

by October 18, 2019

The access rates in Bugiri vary from 43 % in Kapyanga Sub-County to 95 % in Muterere Sub-County. Bugiri has 1,268 domestic water points which serve a total of 294,508 people – 278,964 in rural areas. 74 water points have been non-functional for over 5 years and are considered abandoned. Bugiri has 2 piped schemes.

Access

67%

Rural Functionality

94%

Equity

124

Management

93%

Gender

96%

Population Density (people/km2) and Population

50 250 1,000 2,000
  100 500 1,500  
BDH Budhaya 407
Budhaya
Population 407
BTC Bugiri TC 1,876
Bugiri TC
Population 1,876
BLS Bulesa 487
Bulesa
Population 487
BLD Bulidha 431
Bulidha
Population 431
BWN Buwunga 461
Buwunga
Population 461
IWM Iwemba 319
Iwemba
Population 319
MTR Muterere 508
Muterere
Population 508
NNK Nankoma 542
Nankoma
Population 542
BLG Buluguyi 273
Buluguyi
Population 273
KPY Kapyanga 478
Kapyanga
Population 478
NBK Nabukalu 336
Nabukalu
Population 336

Population figures are projections to the above mentioned date based on UBOS census 2014 and district growth rates. Population density is calculated on land area only. Boundaries reflect the preliminary status only.

Access to Safe Water

20 % 60 %
  40 % 80 %
Total Access 67 %
Rural Access 66 %
Urban Access 95 %

BDH Budhaya 59 %
Budhaya
Population Served 19,800
BLD Bulidha 95 %
Bulidha
Population Served 27,431
BLG Buluguyi 64 %
Buluguyi
Population Served 23,824
BLS Bulesa NWSC
Bulesa
Population Served NWSC
BTC Bugiri TC NWSC
Bugiri TC
Population Served NWSC
BWN Buwunga 62 %
Buwunga
Population Served 34,542
IWM Iwemba 61 %
Iwemba
Population Served 14,100
KPY Kapyanga 43 %
Kapyanga
Population Served 29,800
MTR Muterere 95 %
Muterere
Population Served 31,494
NBK Nabukalu 59 %
Nabukalu
Population Served 25,742
NNK Nankoma 86 %
Nankoma
Population Served 42,200

Access to safe water is the ratio of people served by a safe water point and piped water supply to the total population.
The calculation is based on an estimated number of people per water point type. Maximum access rate can be 95%.

Access to Safe Water

20 % 60 %
  40 % 80 %
Total Access 67 %
Rural Access 66 %
Urban Access 95 %

BDH Budhaya 59 %
Budhaya
Population Served 19,800
BLD Bulidha 95 %
Bulidha
Population Served 27,431
BLG Buluguyi 64 %
Buluguyi
Population Served 23,824
BLS Bulesa NWSC
Bulesa
Population Served NWSC
BTC Bugiri TC NWSC
Bugiri TC
Population Served NWSC
BWN Buwunga 62 %
Buwunga
Population Served 34,542
IWM Iwemba 61 %
Iwemba
Population Served 14,100
KPY Kapyanga 43 %
Kapyanga
Population Served 29,800
MTR Muterere 95 %
Muterere
Population Served 31,494
NBK Nabukalu 59 %
Nabukalu
Population Served 25,742
NNK Nankoma 86 %
Nankoma
Population Served 42,200

Access to safe water is the ratio of people served by a safe water point and piped water supply to the total population.
The calculation is based on an estimated number of people per water point type. Maximum access rate can be 95%.

Functionality of Point Water Sources

60 % 80 %
70 % 90 %
Rural Functionality 94 %
Urban Functionality 100 %

BDH Budhaya 99 %
Budhaya
Functional Sources 66
BLD Bulidha 95 %
Bulidha
Functional Sources 209
BLG Buluguyi 81 %
Buluguyi
Functional Sources 73
BLS Bulesa NWSC
Bulesa
Functional Sources 102
BTC Bugiri TC NWSC
Bugiri TC
Functional Sources 77
BWN Buwunga 97 %
Buwunga
Functional Sources 111
IWM Iwemba 94 %
Iwemba
Functional Sources 45
KPY Kapyanga 93 %
Kapyanga
Functional Sources 103
MTR Muterere 88 %
Muterere
Functional Sources 134
NBK Nabukalu 98 %
Nabukalu
Functional Sources 78
NNK Nankoma 99 %
Nankoma
Functional Sources 156

Functionality is the ratio of functional water sources to all water sources. Sources not operating for five or more years are assumed to be abandoned, and hence are not included in the calculation.

People served per technology

Reasons for non-functionality

Type of Management

Source of Funding

District Water Supply Summary

Sub-CountyUrban/
Rural
PopulationPopulation
Served
AccessFunctionalityPoint Water SourcesPiped Water Systems
Protected
springs
Shallow wellsDeep boreholesRainwater
harvesting tanks
DamsValley
tanks
PSP/Kiosk, Tap standsYTHHICNWSC
RUWfPFNFTotFNFTotFNFTotFNFTotFNFTotFNFTotFNFTot
BUKOOLI                               
 1 NabukaluRural43,52625,74259%98%--4-41021257-577-7------------No
 2 KapyangaRural69,83429,80043%93%--296351011164165---------------No
 3 BudhayaRural33,79419,80059%99%--12-1231451-51---------------No
 4 MuterereRural33,15231,49495%88%--326381238969512416------------No
 5 BuluguyiRural37,43023,82464%81%--17320628481058224------------No
 6 BuwungaRural55,61134,54262%97%--27-27821069170718------------No
 7 BulidhaRural28,87527,43195%95%--10-10491505115292698------74115-1No
 8 BulesaRural47,269NWSCNWSC94%--15-1563977380415------------Yes
 9 Bugiri TCUrban16,362NWSCNWSC-100%-3-336-3610-102-2------26-2677932108Yes
 10 NankomaRural48,98042,20086%99%--43-4313-1393194---------718---No
 11 IwembaRural22,99314,10061%94%--5161011130131---------------No
Total 437,826294,50867941000197162131521516767924703126141400000004054578432109No
District 437,826294,50867941000197162131521516767924703126141400000004054578432109No

F = Functional; NF = Non-Functional; Tot = Total; YT = Yard Tap; HH = Household Connections; IC = Institutional Connections

Piped Water Supply Systems

Type of Scheme/GFSNumber of
Schemes
Functionality of SystemType of ManagementWB in place
FunctionalNon-FunctionalPartially FunctionalPrivate OperatorWSCPrivate/IndividualNWSCOtherYesNo
Unknown/Not GFS20000001000
Groundwater based/Not GFS21100101020
Surface Water Based/Unknown11000001010
Total52100103030

GFS = Gravity Flow Scheme; WB = Water Board; WSC = Water Source Committee